793 research outputs found

    Clinical outcomes of peri‐implantitis treatment and supportive care: A systematic review

    Get PDF
    To report the clinical outcomes for patients with implants treated for peri-implantitis who subsequently received supportive care (supportive peri-implant/periodontal therapy) for at least 3 years. A systematic search of multiple electronic databases, grey literature and hand searching, without language restriction, to identify studies including ≥10 patients was constructed. Data and risk of bias were explored qualitatively. Estimated cumulative survival at the implant- and patient-level was pooled with random-effects meta-analysis and explored for publication bias (funnel plot) at different time intervals. The search identified 5,761 studies. Of 83 records selected during screening, 65 were excluded through independent review (kappa = 0.94), with 18 retained for qualitative and 13 of those for quantitative assessments. On average, studies included 26 patients (median, IQR 21-32), with 36 implants (median, IQR 26-45). Study designs (case definitions of peri-implantitis, peri-implantitis treatment, supportive care) and population characteristics (patient, implant and prosthesis characteristics) varied markedly. Data extraction was affected by reduced reporting quality, but over 75% of studies had low risk of bias. Implant survival was 81.73%-100% at 3 years (seven studies), 74.09%-100% at 4 years (three studies), 76.03%-100% at 5 years (four studies) and 69.63%-98.72% at 7 years (two studies). Success and recurrence definitions were reported in five and two studies respectively, were heterogeneous, and those outcomes were unable to be explored quantitatively. Therapy of peri-implantitis followed by regular supportive care resulted in high patient- and implant-level survival in the medium to long term. Favourable results were reported, with clinical improvements and stable peri-implant bone levels in the majority of patients

    Elevated protein kinase C alpha expression may be predictive of tamoxifen treatment failure

    Get PDF
    We previously reported that stable transfection of protein kinase C alpha (PKCα) into T47D human breast cancer cells results in tamoxifen (TAM)-resistant tumour growth. Relevance of PKCα expression in clinical specimens was determined by comparing PKCα expression in tumours from patients exhibiting disease recurrence with patients remaining disease-free following TAM treatment. Our results suggest that PKCα expression may predict TAM treatment failure

    EO-Alert: A Satellite Architecture for Detection and Monitoring of Extreme Events in Real Time

    Get PDF
    This paper presents the architecture and results achieved by the EO-ALERT H2020 project. EO-ALERT proposes the definition and development of the next-generation Earth Observation (EO) data processing chain, based on a novel flight segment architecture that moves optimised key EO data processing elements from the ground segment to onboard the satellite, with the aim of delivering the EO products to the end user with very low latency (in almost real-time). This paper presents the EO-ALERT architecture, its performance and hardware. Performances are presented for two reference user scenarios; ship detection and extreme weather nowcasting/monitoring. The hardware testing results show that, when implemented using Commercial Off-The-Shelf (COTS) components and available communication links, the proposed architecture can deliver EO products and alerts to the end user with a latency lower than one-point-five minutes, for both SAR and Optical Very High Resolution (VHR) missions, demonstrating the viability of the EO-ALERT concept and architecture

    Prevention and treatment of peri-implant diseases-The EFP S3 level clinical practice guideline.

    Get PDF
    BACKGROUND: The recently published Clinical Practice Guidelines (CPGs) for the treatment of stages I-IV periodontitis provided evidence-based recommendations for treating periodontitis patients, defined according to the 2018 classification. Peri-implant diseases were also re-defined in the 2018 classification. It is well established that both peri-implant mucositis and peri-implantitis are highly prevalent. In addition, peri-implantitis is particularly challenging to manage and is accompanied by significant morbidity. AIM: To develop an S3 level CPG for the prevention and treatment of peri-implant diseases, focusing on the implementation of interdisciplinary approaches required to prevent the development of peri-implant diseases or their recurrence, and to treat/rehabilitate patients with dental implants following the development of peri-implant diseases. MATERIALS AND METHODS: This S3 level CPG was developed by the European Federation of Periodontology, following methodological guidance from the Association of Scientific Medical Societies in Germany and the Grading of Recommendations Assessment, Development and Evaluation process. A rigorous and transparent process included synthesis of relevant research in 13 specifically commissioned systematic reviews, evaluation of the quality and strength of evidence, formulation of specific recommendations, and a structured consensus process involving leading experts and a broad base of stakeholders. RESULTS: The S3 level CPG for the prevention and treatment of peri-implant diseases culminated in the recommendation for implementation of various different interventions before, during and after implant placement/loading. Prevention of peri-implant diseases should commence when dental implants are planned, surgically placed and prosthetically loaded. Once the implants are loaded and in function, a supportive peri-implant care programme should be structured, including periodical assessment of peri-implant tissue health. If peri-implant mucositis or peri-implantitis are detected, appropriate treatments for their management must be rendered. CONCLUSION: The present S3 level CPG informs clinical practice, health systems, policymakers and, indirectly, the public on the available and most effective modalities to maintain healthy peri-implant tissues, and to manage peri-implant diseases, according to the available evidence at the time of publication

    Studies of adsorbents and pressure/vacuum swing adsorption for co2 capture

    Get PDF
    The capture of carbon dioxide via Pressure/Vacuum Swing Adsorption (PSA/VPSA) has been examined experimentally and mathematically. The adopted method was a two bed/four step process, known as the Skarstrom Cycle. Pelletised and calcined SBA-15 powder has been modified with a monoamine, a diamine and a triamine and has been tested in a PSA configuration. The performance of the monoamine modified SBA-15 was more than doubled with the presence of immobilised polyamine groups (diamine/triamine modified SBA-15) extending the adsorption capacity of the material (chemisorption), but still not comparable to the performance of zeolite 13X (physisorption) in terms of performance, stability and reproducibility. These results will be compared to the performance of four Metal Organic Frameworks, ZIF-8, ZIF-67, UiO-66 and CuBTC which are innovative and promising materials with several applications. Experimentally, the performance of zeolites and amine modified mesoporous silicas has been investigated for different experimental conditions (cycle time, pressure ratio, feed/purge ratio). This work is further supported by theoretical studies of PSA which employs a mathematical model based on linear coupled macropore and micropore diffusion and, where appropriate, reaction. These simulations are performed using gProms

    Immediate vs. Delayed Implant Placement after Anterior Single Tooth Extraction: The Timing Randomised Controlled Clinical Trial.

    Get PDF
    to compare need for bone augmentation, surgical complications, periodontal, radiographic, aesthetic and patient reported outcomes in subjects receiving implant placement at the time of extraction (IMI) or 12 weeks thereafter. METHODS: Subjects requiring single tooth extraction in the anterior and premolar areas were recruited in 7 private practices. Implant position and choice of platform were restoratively driven. Measurements were performed by calibrated and masked examiners. RESULTS: IMI was unfeasible in 7.5% of cases. 124 subjects were randomized. One implant was lost in the IMI group. IMI required bone augmentation in 72% of cases compared with 43.9% for delayed (P=0.01), while wound failure occurred in 26.1% and 5.3% of cases, respectively (P=0.02). At 1 year, IMI had deeper probing depths (4.1±1.2 mm vs. 3.3±1.1 mm, P<0.01). A trend for greater radiographic bone loss was observed at IMI over the initial 3-year period (Ptrend<0.01). Inadequate pink aesthetic scores were obtained in 19% of delayed and in 42% of IMI implant cases (P=0.03). No differences in patient reported outcomes were observed. CONCLUSIONS: Immediate implant placement should not be recommended when aesthetics are important, IMI should be limited to selected cases. Longer follow-up is needed to assess differences in complication rates. This article is protected by copyright. All rights reserved

    Extracorporeal CO 2 Removal During Renal Replacement Therapy to Allow Lung-Protective Ventilation in Patients With COVID-19-Associated Acute Respiratory Distress Syndrome

    Get PDF
    The aim of this retrospective multicenter observational study is to test the feasibility and safety of a combined extracorporeal CO 2 removal (ECCO 2 R) plus renal replacement therapy (RRT) system to use an ultraprotective ventilator setting while maintaining (1) an effective support of renal function and (2) values of pH within the physiologic limits in a cohort of coronavirus infectious disease 2019 (COVID-19) patients. Among COVID-19 patients admitted to the intensive care unit of 9 participating hospitals, 27 patients with acute respiratory distress syndrome (ARDS) and acute kidney injury (AKI) requiring invasive mechanical ventilation undergoing ECCO 2 R-plus-RRT treatment were included in the analysis. The treatment allowed to reduce V T from 6.0 ± 0.6 mL/kg at baseline to 4.8 ± 0.8, 4.6 ± 1.0, and 4.3 ± 0.3 mL/kg, driving pressure (ΔP) from 19.8 ± 2.5 cm H 2 O to 14.8 ± 3.6, 14.38 ± 4.1 and 10.2 ± 1.6 cm H 2 O after 24 hours, 48 hours, and at discontinuation of ECCO 2 R-plus-RRT (T3), respectively ( p &lt; 0.001). PaCO 2 and pH remained stable. Plasma creatinine decreased over the study period from 3.30 ± 1.27 to 1.90 ± 1.30 and 1.27 ± 0.90 mg/dL after 24 and 48 hours of treatment, respectively ( p &lt; 0.01). No patient-related events associated with the extracorporeal system were reported. These data show that in patients with COVID-19-induced ARDS and AKI, ECCO 2 R-plus-RRT is effective in allowing ultraprotective ventilator settings while maintaining an effective support of renal function and values of pH within physiologic limits

    EO-ALERT: NEXT GENERATION SATELLITE PROCESSING CHAIN FOR RAPID CIVIL ALERTS

    Get PDF
    In this paper, we provide an overview of the H2020 EU project EO-ALERT. The aim of EO-ALERT is to propose the definition and development of the next generation Earth observation (EO) data and processing chain, based on a novel flight segment architecture moving optimised key EO data processing elements from the ground segment to on-board the satellite. The objective is to address the need for increased throughput in EO data chain, delivering EO products to the end user with very low latency
    corecore